Genie® Runabout®aerial work platforms are designed to enhance productivity in the workplace. Flexible features on the Genie GR™ models offer convenience at a low cost. Their lightweight construction makes them easy to maneuver, use and transport, delivering excellent uptime. Each model offers a variety of options and accessories to customize the machine to match the application. Genie aerial work platforms offer an economical solution for all operators’ access needs.
- Home
- GR-12
GR-12
Vertical Mast Lifts

Genie® Runabout® GR™-12 lifts are compact, low-weight machines that increase productivity on the job. Efficient operation and convenient setup these Genie Runabout lifts are ideal for warehousing, stock-picking, transporting, inventory management and general maintenance.
Overview
- Precise up and over access — with outreach capability to get virtually any job done
- Driveable when fully elevated
- Zero inside turning radius, 140° rotating jib and 350° non-continuous hydraulic turntable for precise positioning
- Narrow width to fit through doorways and in most passenger elevators
| Specification | Value |
|---|---|
| Working Height | 17 ft 4 in | 5.45 m |
| Capacity | 500 lb | 227 kg |
| Stowed Height | 5 ft 10 in | 1.78 m |
| Machine Width | 2 ft 5.5 in | 75 cm |
| Machine Weight | 1,681 lb | 763 kg |
- 2025 - Spec Sheet GR12_GR15_GR20 ANSI (SEA) ANSI
- 2025 - Spec Sheet GR12_GR15_GR20 ANSI (SEA) CE
- To view earlier versions of this specification sheet, please click here and look up for your machine Operator Manual by serial number.
The relevant specification data will be on the last page.
Image and Video Gallery
Related News
-
![高空车选购]()
-
![吉尼客户价值故事]()
-
![剪型高空作业平台]()
-
![高空作业平台案例]()
-
![海南会展中心安全建设]()
-
![吉尼客户价值故事]()
-
![Genie Scissor Lift]()
Clearing Up the Confusion: Fall Protection Requirements on Group B MEWPs
When it comes to using fall protection equipment for on mobile elevating work platforms (MEWPs), many still do not fully understand, or comprehend, the requirements in the ANSI A92 and CSA B354 standards, as well as the OSHA and OHS requirements, for fall protection on MEWPs in the United States and Canada.
- Sep 26, 2019
-
![COPY IMAGE 2 - S-85_XC_Azzura-1199]()
Updated Training Requirements
One of the biggest challenges facing our industry today is how to increase awareness about why safety training is so important. As the North American aerial industry implements the new ANSI and CSA standards changes, companies need to understand their responsibilities regarding training requirements for Mobile Elevating Work Platforms (MEWPs).
- Sep 26, 2019
-
ANSI & CSA Standards | Ask Me Anything June 10th-14th, 2019
Welcome to Ask Me Anything with Scott Owyen on the new ANSI and CSA Standards!
- Jun 18, 2019
-
Purchasing MEWPs Compliant with Regional Standards
In the United States, the Occupational Safety and Health Administration, or OSHA, is the primary enforcement agency for mobile elevated work platform (MEWP), or commonly known as aerial work platform (AWP), safety on the jobsite.
- Jun 18, 2019
-
The Brand Matters When Purchasing Used MEWP Equipment
There are reasons some aerial work platforms (AWP) is considered a top-tier brand, maintains its value and garners a fairly premium price in the used market.
- Jun 18, 2019
-
HBV, Spelle Germany Adds 105 Meters of Working Height to Its Fleet
This January, family-owned rental company HBV Hydraulikbühnen-Verleih GmbH (HBV), based in Spelle, northwestern Germany, received delivery of three Genie® Xtra Capacity™ (XC™) telescopic boom lifts.
- Jun 18, 2019
-
How Aerial Operator Protection Evolves
When developing new operator protection technology, you must reach beyond equipment and listen to the workers who are using it each and every day.
- Jun 18, 2019
-
A92 Minute: Supervisor Training
Check out this Genie A92 Minute on conducting Supervisor Training in accordance with the updated ANSI A92 and CSA B354 Standards.
- Jun 18, 2019
-
![]()
-
![]()
-
![Genie Telescopic Boom]()
-
![Genie Telescopic Boom]()
-
![Genie Z Boom]()
-
![Genie GRC]()
-
![Genie Articulated Boom Lift]()
Changes to the ANSI and CSA Standards You Need to Know About
The current ANSI and CSA standards for safe use and training have not been updated for many years (the current ANSI boom, scissor lift and manually propelled standards were last updated in 2006, and CSA standards go back even further).
- Dec 04, 2018
-
![Genie Stick Boom]()
-
![Genie Z Boom]()
-
![Genie Scissor Lift]()
-
![Genie Load Sense]()
-
![Genie Stick Boom]()
Responding to the New Normal
Changes to North American standards (ANSI A92 in the United States and CSA B354 in Canada) are expected to come in 2018 and will create a new “normal” for mobile elevated work platforms (MEWPs), formerly known as aerial work platforms (AWPs), worldwide.
- Dec 04, 2018
-
![Genie Z-33/18]()
Addressing the Challenges of the Upcoming Changes to the ANSI A92 Standards
The upcoming implementation of the new ANSI A92.22 Safe Use and A92.24 Training Standards for Mobile Elevating Work Platforms (MEWPs) in the United States is creating quite a bit of confusion in the industry.
- Dec 04, 2018
-
Case Study: Electrical Training Alliance Partners with Genie to Offer Aerial Operators’ Training for the New Generation of Apprentices and Journeymen
- Apr 12, 2018